Linshang as an uv integrator supplier produces uv power puck for sale, provide a fair price of uv energy meter for led,mercury vapor lamp curing and uv exposure machine. The uv power puck ii reading includes total energy and peak irradiance of four bands. When you plug in the power puck ii, windows will try to find the server. Jun 02, 20 a brief introduction to using the eit power puck ii integrating radiometer.
The enhancements are described on the pdf files downloaded along the update, and are the following. Faster sample rates anda thermocouple are available with the eitpowermap ii. Eit online measurement solutions provide continuous monitoring of uv systems to detect uv curing problems in realtime. The uv power puck ii is available in two combinations of four eit bandwidths. Latest manual and software update for your power master ii, click here. Turn the unit on by pressing either the select or the reset button. Power puck iipower puck ii profiler eit instrument markets, united states request a quote. Uvicure plus ii is a single band instrument choose uva, uvb, uvc or uvv at. This software is not compatible and will not work with standard puck units. The instrument needs to say profiler in the top line when first turned on in order to use this software. Apr 24, 2015 learn how to measure the uv output of your flatbed digital inkjet printing press using the eit power puck ii and powerview ii software. Eit na uv power puck ii view details eit sp65eit photo intensity meter view details eit um365hs photometer view details eit lm908241 uv intensity meter view details eit 960 open channel flowmeter view details eit power puck ii uv power view details eit mc2a micro cure view details eit pp2hu uv power puck ii view details.
The eit program is designed so you have the option to rotate through different areas within enmax. Microcure starter kit 2microcure radiometers and 1data read. The standard 10 watt unit works well for high power curing applications. Data screen mode, graph screen mode and reference mode from uv power puck ii and uvi. The transferred data can be analyzed with eits powerview software ii which allows. Equipped with pc software which can generate data curve and print out test reports. Learn how to measure the uv output of your flatbed digital inkjet printing press using the eit power puck ii and powerview ii software. The most appropriate choice can be made by considering cost. The radiometers are nist traceable and most are available in a choice of four standard wavelengths. The profiler version of the power puck ii functions as a standard power puck ii instrument while adding the ability to transfer the collected data and irradiance profile to a computer for. The standard range 10 watt works well for high power curing applications. Eits current software programs are used to transfer and analyze the data collected by the powermap ii and profiling versions of the ledcure, power puck ii and uvicure plus ii radiometers. Power puck iiuvicure plus nonprofiling data only program. The life cycle of an eit radiometer often lasts longer than the life cycle of an operating system.
Equipped with pc software which can generate data curve and print. The uvicure plus ii or uv power puck ii instruments are available in three dynamic operating ranges. Eit products designed to measure uv broadband mercurymercury additive sources are in this section. Eit calibration micro precision provides calibration for all types of eit instruments, calibration test equipment sale and repair. The profiler unit allows the transfer of data including the irradiance profile w vs. Used in curing applications of inks, adhesives, soldermasks, and. A method and an inkjet printing device 10 are disclosed for single pass printing on an inkreceiver 50 having a surface 51, the device including a plurality of sets of nozzles 1518, 2528 for jetting n inks on the surface 51, wherein n is larger than or equal to one, the n inks including a first ink, and wherein the plurality of sets of nozzles includes a first 15 and a. Eit uvicure plus ii uva high power radiometer is an electrooptic radiometer that is designed to measure uv energy and irradiance.
The data view screen lists the total energy density jcm2 and the peak power density wcm2 for each active spectral channel. The powermap ii is 60% smaller than its predecessor, however, it features a larger internal memory and rapid data transfer to powerview software, and is able to measure the four uv spectral regions uva, uvb, uvc, uvv. With user selectable sample rates, these new instruments can be used for fast conveyor lines or slower lines, and measurements are compatible with other eit products. Uv led energy meter is the worlds first uv energy meter for testing uv led lamp, which the range of spectrum is 340420nm. The transferred data can be analyzed with eits powerview iipowerview iii software to allow analysis, sharing, storage and comparison of readings. The profiler versions of their power puck iiuvicure plus ii function as a standard units with the added ability to transfer the irradiance profile to a computer. For example, the price of eit uv power puck ii is basically more than 2,000 us dollars, while the price of linshang uv energy meter is only 442 us dollars. Power puck ii radiometer uv01451 uvitron online store. The instruments can be configured in graph irradiance profile on the display, all channel data or reference stored reading modes. National instruments labview based programming designed for windows xp, windows nt, windows vista and windows 7. A brief introduction to using the eit power puck ii integrating radiometer.
Eit offers complete electronic design, assembly, test and order fulfillment services to improve time to market, to reduce cost and to insure product performance and quality. The transferred data can be analyzed with eits powerview software ii which allows the user to easily compare files to look at the. Push buttons lcd display select battery door reset uv sensors uv power puck a b v c uvicure plus a figure 3 uv power puck and uvicure plus physical features 8 operation doing an exposure run with uv power puck 1. Eit uv power puck ii ultraviolet irradiation meter uv. Power puck iipower puck ii profiler eit instrument markets. Power puck iipower puck ii profiler eit instrument. Uvintegrator uv curable coating systems for measuring the uv intensity in the peak uv drying system w cm. The eit uv power puck ii is a small, portable, selfcontained radiometer that measures uv peak irradiance wattscm. The difference between eit uv power puck ii and ls128. The profiler versions of their power puck ii and uvicure plus ii function as a standard power puck ii or uvicure plus ii instrument while adding the ability to transfer the collected data and irradiance profile to.
Usb interface, computer software can read the detailed record data, curve analysis and print output test report. For the 32bit version, load into the x86 directory. Powerview ii electronics manufacturing services eit llc. The average temperature and peak temperature readings collected by the thermocouple are also presented. Uv power puck ii profiler and uvicure plus ii profiler. Eit radiometers and online monitoring equipment provide uv users with the widest choice of instruments on the market. Uv energy meter uv power puck for 340nm to 420nm uv led uv curing. Power puck ii profiler and uvicure plus ii profiler. It offers adjustable sampling rates, easy to use software, reference modes, and a choice of one uva, uva2, uvb, uvc, uvv eit. The power puck ii is a 4band instrument with uva, uvb, uvc and uvv bands. Used in curing applications of inks, adhesives, soldermasks, and epoxies not for use in web press applications incorporates four separate spectral.
Eit uv powermap spectral radiometer measuring device package. The uv power puck ii simultaneously measures four different ranges of ultraviolet wavelengths with one pass through the uv process. The transferred data can be analyzed with eits powerview iii software to allow analysis, sharing, storage and comparison of readings. If two files are open, data view shows the differences between readings as absolute values and as percentages. The uva2 power puck ii version for capturing led sources in the 380410 nm. Eit uv power puck spectral radiometer measuring device package w case. The radiometer is able to measure uv irradiance wcm2, total energy density jcm2, and uv irradiance as a function of time. The powerpuck from luxdrive is a current regulated led driver, designed to automatically vary its output voltage as the forward voltage of an led changes, all while maintaining a constant current output. Uv energy meter uv power puck for 340nm to 420nm uv led uv. The uv power puck ii is now available in three operating or dynamic ranges. Eit uv power puck ii ultraviolet irradiation meter uv meter 4 uv bands measuring intensity energy temperature.
Powerpuck ii profiler gentec adhesives and dispensing. The profiler versions of their power puck iiuvicure plus ii function as a standard unit with the added ability to transfer the irradiance profile to a computer. The powerview iii software will work eits powermap ii and profiler versions of the ledcure, power puck ii and uvicure plus ii. Alpha uv systems australias premier supplier of uv. The power puck ii four band and uvicure plus ii single band are small, portable, selfcontained radiometers that measure uv peak irradiance wattscm. The profiler unit allows the transfer of data including the irradiance.
The uv power puck ii measures 4 different uv bands simultaneously. The power puck ii is a portable selfcontained radiometer that can measure uv peak irradiance and energy density during uv curing, and the profiler can download data to a computer for further analysis. Before downloading this software, confirm that your power puck ii, uvicure plus ii or ledcure is a profiler enabled instrument. Eit uv power puck ii radiometers the radiometers that first set the standard for the uv industry are now setting a new standard with advanced features and an easy to read display, multiple user selectable modes, and pc communications for data logging and trending capabilities. The sample rate of the irradiance profile transferred to acomputer is 128 hz. The midrange 1 watt works well with low power arc lamps and in applications with lamps that are non focused or away from the cure surface. It offers adjustable sampling rates, easy to use software, reference modes, and portability. The new mid range unit 1 watt works well with lower power arc lamps and applications with lamps that are nonfocused or a little further away from the cure surface. To install, remove the current version of powermaster ii basic. Eit radiometers are available in single and fourband configurations in different dynamic ranges. Uv integratoruv energy meter priceuv power puck for sale.
It can be configured in graph, datachannel, and reference modes. The capacity of the power puck ii and uvicure plus ii profilers in profiler mode is sufficient to collect data for 100 minutes. Eit na uv power puck ii view details eit sp65 eit photo intensity meter view details eit um365hs photometer view details eit lm908241 uv intensity meter view details eit 960 open channel flowmeter view details eit power puck ii uv power view details eit mc2a micro cure view details eit pp2hu uv power puck ii view details. Uvicure plus ii and uv power puck ii are widely used throughout the global uv industry.
The uvicure plus ii or uv power puck ii instruments are available in three dynamic. The profiler versions of their power puck ii and uvicure plus ii function as a standard power puck ii or uvicure plus ii instrument while adding the ability to transfer the collected data and irradiance profile to a computer via a usb connector. Alpha uv systems australias premier supplier of uv curing. Eit uvicure plus ii uvv high power radiometer is an electrooptic radiometer that is designed to measure uv energy and irradiance. It offers adjustable sampling rates, easy to use software, reference modes, and a choice of one uva, uva2, uvb, uvc, uvv eit wavelength bands. The new eit instrument markets uvicure plus ii and uv power puck ii are advanced versions of the uvicure plus and uv power puck widely used throughout the global uv industry. Eit radiometers are designed to be durable and long lasting. It can test 365nm, 385nm, 395nm and other wavelength uv led light, is the first choice for uv curing energy meter. Eit datasheets electronic manufacturing services, assembly. Eit calibration micro precision is an iso 17025 a2la accredited lab that performs eit calibration. At present, many brands of uv radiometer pucks perform well in terms of product performance, but the price is generally higher. The uvicure plus ii or uv power puck ii instruments are now available in three operating or dynamic ranges. The 2008b series powerpuck is a, 532vdc input, constant current output led driver for powering highbrightness hb leds.